Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 64
Filter
1.
Dental press j. orthod. (Impr.) ; 22(6): 61-67, Nov.-Dec. 2017. tab, graf
Article in English | LILACS | ID: biblio-891107

ABSTRACT

ABSTRACT Objective: Evaluate changes in the force system of T-Loop Springs (TLS) preactivated by curvature, due to stress relaxation. Methods: Ninety TLSs measuring 6 x 10 mm, produced out with 0.017 x 0.025-in TMA® wire and preactived by gradual curvature, were randomly distributed into nine groups according to time point of evaluation. Group 1 was tested immediately after spring preactivation and stress relief, by trial activation. The other eight groups were tested after 24, 48 and 72 hours, 1, 2, 4, 8 and 12 weeks, respectively. Using a moment transducer coupled to a digital extensometer indicator adapted to a universal testing machine, the amount of horizontal force, moment and moment-to-force ratios were recorded at every 0.5 mm of deactivation from 5 mm of the initial activation, in an interbracket distance of 23 mm. Results: The horizontal forces decreased gradually among the groups (p< 0.001) and the moments showed a significant and slow decrease over time among the groups (p< 0.001). All groups produced similar M/F ratios (p= 0.532), with no influence of time. Conclusions: The TLSs preactivated by curvature suffered a gradual deformation over time, which affected the force system, specifically the moments, which affected the horizontal forces produced.


RESUMO Objetivo: avaliar as mudanças no sistema de forças das molas T pré-ativadas por curvatura, devido ao alívio de tensão estrutural. Métodos: noventa molas em forma de "T", medindo 6 mm x 10 mm, confeccionadas com fio de beta-titânio TMA® de 0,017" x 0,025" e pré-ativadas por curvatura gradual, foram distribuídas aleatoriamente em nove grupos, de acordo com o momento de avaliação. O Grupo 1 foi testado imediatamente após a pré-ativação da mola e liberação do estresse, por meio de simulação da ativação. Os outros oito grupos foram divididos conforme o intervalo de tempo testado: após 24, 48 e 72 horas; 1, 2, 4, 8 e 12 semanas. Usando um transdutor de momentos acoplado a um indicador digital para extensometria e adaptado a uma máquina universal de ensaios, as magnitudes da força horizontal, do momento e da proporção momento/força (M/F) foram registradas a cada 0,5 mm de desativação a partir da ativação inicial de 5 mm, utilizando-se uma distância interbraquetes de 23 mm. Resultados: as forças horizontais reduziram-se gradualmente nos grupos (p< 0,001) e o momento apresentou uma queda lenta e significativa ao longo do tempo (p< 0,001). Todos os grupos tiveram proporções M/F semelhantes (p= 0,532), não influenciadas pelo período de tempo. Conclusões: as molas pré-ativadas por curvatura gradual sofreram deformação progressiva ao longo do tempo, o que afetou o sistema de forças - especificamente o momento -, alterando as forças horizontais produzidas.


Subject(s)
Orthodontic Wires , Titanium/chemistry , Orthodontic Appliance Design , Orthodontic Space Closure/instrumentation , Dental Alloys/chemistry , Dental Stress Analysis , Stress, Mechanical , Time Factors , Biomechanical Phenomena , Materials Testing , Random Allocation , Statistics, Nonparametric
2.
Dental press j. orthod. (Impr.) ; 22(1): 38-46, Jan.-Feb. 2017. tab, graf
Article in English | LILACS | ID: biblio-840214

ABSTRACT

ABSTRACT Objective: The aim of this paper was to determine the amount of deformation in four commercial brands of nickel-titanium closed springs. Methods: A total of 130 springs were divided into 13 subgroups, according to their features and manufacturers (Morelli, Orthometric, Ormco and GAC) and activated from 100% to 1000% of the effective length of the nickel-titanium portion present at the spring, at 37 °C. Deactivation data were plotted and deformation was found graphically. The values were compared by analysis of variance and Tukey's post-hoc test. Results: Springs manufactured by Morelli had the same amount of deformation when they were activated up to 700% of Y activation; springs by Orthometric had the same amount of deformation up to 600-700% of Y; springs by Ormco had the same amount of deformation up to 700-800% of Y; and finally, the majority of springs by GAC had similar deformation up to 800%-1000% of activation. All springs tested could be activated up to 700% without rupture. Conclusions: Most subgroups were similarly deformed up to 700% of activation, without rupture of springs. Subgroups 4B, 4C, 4D and 4E showed the same amount of deformation up to 1000% of activation without any rupture at all.


RESUMO Objetivo: o objetivo desse trabalho foi determinar a deformação em molas fechadas de níquel-titânio de quatro marcas comerciais. Métodos: cento e trinta molas foram divididas em treze subgrupos, de acordo com suas características e fabricantes (Morelli, Orthometric, Ormco e GAC), com ativação entre 100% e 1.000% do comprimento efetivo de níquel-titânio presente na mola (Y), a 37 °C. Dados de desativação foram coletados e a deformação foi obtida de forma gráfica. Os valores foram comparados por meio de análise de variância e teste post-hoc de Tukey. Resultados: as molas da Morelli apresentaram a mesma quantidade de deformação considerando-se 700% de ativação de Y; as molas da Orthometric tiveram a mesma quantidade de deformação até 600-700% de Y; as molas da Ormco tiveram a mesma quantidade de deformação até 700-800% de Y; e, por fim, a maioria das molas da GAC apresentou deformação semelhante até 800-1.000% de ativação. Todas as molas testadas puderam ser ativadas até 700% sem ruptura. Conclusões: a maioria dos subgrupos se deformou de maneira semelhante até 700% de ativação, sem ruptura das molas. Os subgrupos 4B, 4C, 4D e 4E demonstraram a mesma quantidade de deformação até 1.000% de ativação, sem nenhuma ruptura.


Subject(s)
Orthodontic Appliances , Titanium , Dental Stress Analysis , Nickel , Materials Testing , Orthodontic Appliance Design , Elasticity , Alloys
3.
Dental press j. orthod. (Impr.) ; 21(3): 46-55, tab, graf
Article in English | LILACS | ID: lil-787911

ABSTRACT

abstract Objective: This paper analyzed whether nickel-titanium closed coil springs (NTCCS) have a different superelastic (SE) behavior according to activation and whether their force plateau corresponds to that informed by the manufacturer. Methods: A total of 160 springs were divided into 16 subgroups according to their features and activated proportionally to the length of the extensible part (NiTi) of the spring (Y). The force values measured were analyzed to determine SE rates and force plateaus, which were mathematically calculated. These plateaus were compared to those informed by the manufacturer. Analysis of variance was accomplished followed by Tukey post-hoc test to detect and analyze differences between groups. Results: All subgroups were SE at the activation of 400% of Y length, except for: subgroups 4B and 3A, which were SE at 300%; subgroups 4E and 4G, which were SE at 500%; and subgroup 3C, which was SE at 600%. Subgroup 3B did not show a SE behavior. Force plateaus depended on activation and, in some subgroups and some activations, were similar to the force informed. Conclusions: Most of the springs showed SE behavior at 400% of activation. Force plateaus are difficult to compare due to lack of information provided by manufacturers.


resumo Objetivo: o presente artigo analisou se as molas helicoidais fechadas de níquel-titânio apresentam superelasticidade (SE), de acordo com a ativação, e se o platô de força medido corresponde ao informado pelo fabricante. Material e Métodos: 160 molas foram divididas em 16 subgrupos, de acordo com suas características, e foram ativadas proporcionalmente ao comprimento da parte extensível (NiTi) da mola (Y). Os valores de força obtidos foram analisados para determinar as taxas de SE e os platôs de força, os quais foram calculados matematicamente - sendo esses platôs comparados aos informados pelos fabricantes. Uma análise de variância foi realizada, seguida do teste post-hoc de Tukey, para detectar e analisar as diferenças entre os grupos. Resultados: todos os subgrupos apresentaram SE em ativação de 400% do comprimento Y, com exceção dos subgrupos 4B e 3A (que apresentaram SE a 300%), dos subgrupos 4E e 4G (com SE a 500%) e do subgrupo 3C (que apresentou SE na ativação de 600%). O subgrupo 3B não apresentou comportamento superelástico. Os platôs de força dependeram da ativação e em alguns subgrupos, em determinadas ativações, foram semelhantes à força informada pelo fabricante. Conclusões: a maioria das molas apresentou comportamento superelástico na ativação de 400%. Os platôs de força são difíceis de ser comparados, devido à falta de informações por parte dos fabricantes.


Subject(s)
Humans , Orthodontic Wires , Titanium , Dental Alloys , Dental Stress Analysis , Nickel , Stress, Mechanical , Materials Testing , Orthodontic Appliance Design , Elasticity
4.
Ortodontia ; 49(2): 163-168, mar.-abr.2016. ilus
Article in Portuguese | LILACS | ID: lil-788872

ABSTRACT

Os alinhadores quase invisíveis continuam atraindo muita atenção dos ortodontistas contemporâneos, e muitas publicações descrevem os passos para confeccionar alinhadores ou apresentam casos clínicos. O objetivo deste artigo foi buscar a fundamentação biomecânica de seu uso na literatura, e discutir a eficiência para os movimentos necessários para a correção das mais diversas más-oclusões. Seja qual for o aparelho utilizado, para que um movimento ocorra com previsibilidade, o controle de forças e momentos devem ser obtidos. O desenvolvimento dos alinhadores vem sendo reportado desde os anos 1940, e muitos recursos foram implementados com a utilização da tecnologia tridimensional de modelos virtuais para a manipulação dos movimentos desejados dos dentes. Pesquisas laboratoriais e clínicas foram discutidas para evidenciar as possibilidades mecânicas desses sistemas e avaliar se eles podem, de fato, ser usados para tratamentos ortodônticos ou meramente para alinhar dentes e realizar pequenos movimentos dentários...


The nearly invisible aligners continue to attract much attention from contemporary orthodontists. Many publications describe the steps for making aligners or present clinical cases. The purpose of this article is to search in literature the biomechanical basis of its use and discuss the efficiency of the movements required for the correction of various malocclusions. Whatever the apparatus used so that a movement occurs predictably, the control forces and moments must be obtained. The development of aligners has been reported since 40’s and many resources have been implemented using three dimensional virtual models technology for handling the desired tooth movement. Laboratory and clinical research were discussed to demonstrate the mechanical possibilities of these systems and assess whether they can in fact be used for orthodontic treatments or merely to align teeth and small tooth movements...


Subject(s)
Humans , Orthodontic Appliances, Removable/trends , Biomechanical Phenomena , Esthetics, Dental
5.
Dental press j. orthod. (Impr.) ; 20(6): 89-96, Nov.-Dec. 2015. tab, graf
Article in English | LILACS | ID: lil-770272

ABSTRACT

Abstract Objective: Evaluation of the force system produced by four brands of b-Ti wires bent into an elaborate design. Methods: A total of 40 T-loop springs (TLS) hand-bent from 0.017 x 0.025-in b-Ti were randomly divided into four groups according to wire brand: TMATM(G1), BETA FLEXYTM (G2), BETA III WIRETM (G3) and BETA CNATM (G4). Forces and moments were recorded by a moment transducer, coupled to a digital extensometer indicator adapted to a testing machine, every 0.5 mm of deactivation from 5 mm of the initial activation. The moment-to-force (MF) ratio, the overlapping of the vertical extensions of the TLSs and the load-deflection (LD) ratio were also calculated. To complement the results, the Young's module (YM) of each wire was determined by the slope of the load-deflection graph of a tensile test. The surface chemical composition was also evaluated by an energy dispersive X-ray fluorescence spectrometer. Results: All groups, except for G2, produced similar force levels initially. G3 produced the highest LD rates and G1 and G4 had similar amounts of overlap of the vertical extensions of the TLSs in "neutral position". G1 and G3 delivered the highest levels of moments, and G2 and G3 produced the highest MF ratios. b-Ti wires from G3 produced the highest YM and all groups showed similar composition, except for G2. Conclusion: The four beta-titanium wires analyzed produced different force systems when used in a more elaborate design due to the fact that each wire responds differently to bends.


Resumo Objetivo: avaliar os sistemas de força produzidos por quatro marcas de fios de -Ti, dobrados em formas complexas. Métodos: quarenta molas T-Loop (TLS) dobradas à mão, confeccionadas a partir de fios de -Ti, calibre 0,017" x 0,025", foram aleatoriamente divididas em quatro grupos, de acordo com a marca do fio: TMA (G1), BETA FLEXY (G2), BETA III Wire (G3) e BETA CNA (G4). Forças e momentos foram registrados por um transdutor de momento - acoplado a um extensômetro digital, adaptado a uma máquina de ensaios -, a cada 0,5mm de desativação, a partir de 5mm da ativação inicial. A proporção momento-força (M/F), a sobreposição das extensões verticais das TLSs e a relação carga-deflexão (C/D) também foram calculadas. Para completar os resultados, o módulo de Young (MY) de cada fio foi determinado pelo declive no gráfico de carga-deflexão em um ensaio de tração. Ademais, a composição química da superfície foi avaliada por um espectrômetro de fluorescência de raios X por energia dispersiva. Resultados: todos os grupos, exceto o G2, produziram níveis de força semelhantes, inicialmente. O G3 produziu as maiores taxas de C/D, enquanto G1 e G4 tiveram quantidades similares de sobreposição das extensões verticais das TLSs em posição neutra. G1 e G3 geraram os mais altos níveis de momentos, enquanto G2 e G3 produziram os mais altos índices de M/F. Os fios -Ti do G3 produziram o maior MY, e todos os grupos apresentaram composição semelhante, exceto G2. Conclusão: os quatro fios de beta-titânio analisados produziram diferentes sistemas de forças, quando utilizados para formas mais complexas, devido ao fato de que cada fio responde de forma diversa à confecção de dobras.


Subject(s)
Stress, Mechanical , Orthodontic Wires , Titanium , Materials Testing , Dental Alloys
6.
Ortodontia ; 48(5): 411-419, set.-out.2015. ilus
Article in Portuguese | LILACS | ID: lil-783992

ABSTRACT

Embora incomum, a impacção de incisivos centrais superiores é geralmente diagnosticada precocemente, devido à importância destes dentes na função mastigatória e na aparência do indivíduo. O objetivo deste trabalho foi relatar dois casos clínicos nos quais uma abordagem cirúrgica e ortodôntica foi realizada para tratar incisivos centrais impactados. Em ambos os casos, foi realizada a expansão rápida da maxila com o auxílio de um aparelho disjuntor de Haas. Da mesma forma, foi efetuada a exposição cirúrgica e o tracionamento ortodôntico do incisivo central superior impactado. Forças ortodônticas leves foram utilizadas durante todo o tracionamento ortodôntico, as quais foram aplicadas em arcos rígidos. Ao final do tratamento, os dentes apresentavam uma altura de coroa clínica adequada, contornos gengivais satisfatórios e vitalidade pulpar. De acordo com o desfecho clínico dos dois casos apresentados, pôde-se concluir que a exposição cirúrgica bem planejada, associada ao tracionamento ortodôntico dos dentes impactados contribuiu para os resultados positivos observados neste estudo...


Although uncommon, the impaction of maxillary central incisors is usually early diagnosed, due to the importance of these teeth in masticatory function and appearance of the individual. The aim of this paper was to report two clinical cases, in which surgical and orthodontic approach were performed, in order to treat impacted central incisors. In both cases, we have done the rapid disjunction of the midpalatal suture, as well as exposure and orthodontic traction of the impacted maxillary central incisor. Light forces were used during the all the orthodontic traction, which were applied on rigid archs. It was noted that the teeth presented adequate clinical crown height, satisfactory gingival contours and pulp vitality. It can be concluded that a well-planned surgical exposure of the impacted teeth in association with orthodontic traction contributed to periodontal and aesthetic optimal treatment outcomes...


Subject(s)
Humans , Male , Child , Incisor/surgery , Orthodontics, Corrective , Tooth, Impacted
7.
Braz. j. oral sci ; 14(3): 251-255, July-Sept. 2015. tab, graf
Article in English | LILACS, BBO | ID: lil-770531

ABSTRACT

Abstract Aim : To assess the surface topography and chemical composition of three brands of as-received mini-implants (SIN(r), Morelli(r), and Conexao(r)). Methods: Twelve mini-implants of each brand were analyzed by scanning electron microscopy and energy dispersive X-ray (EDX). Results: There was no significant differences among SIN(r), Morelli(r), and Conexao(r) mini-implants comparing their surface topography by visualization of SEM micrographs and analysis of scores. The EDX analysis showed statistically significant difference among them for the amount of Ti, Al and V. Miniimplants SIN(r)presented also N and O in their composition. Conclusions: In conclusion, the miniimplants Morelli(r), SIN(r) and Conexao(r) presented Ti as main component of the alloy. Remaining components, such as Al and V, were also observed in all the analyzed brands, with differences among them. Only SIN(r)mini-implants presented N and O. As far as surface topography is concerned, there are no differences among the three brands of mini-implants.


Subject(s)
Orthodontics , Titanium , Orthodontic Anchorage Procedures
8.
Braz. oral res. (Online) ; 29(1): 1-8, 2015. tab, ilus
Article in English | LILACS | ID: lil-777219

ABSTRACT

This study aims at comparing conventional and nickel-free metal bracket surface characteristics with elemental composition by scanning electron microscopy (SEM), using energy dispersive spectroscopy (EDS). The sample consisted of 40 lower incisor brackets divided into four groups: ABZ = conventional brackets, Kirium Abzil 3M® (n = 10); RL = conventional brackets, Roth Light Morelli® (n = 10); NF = nickel-free brackets, Nickel-Free Morelli® (n = 10); and RM = nickel-free brackets, Roth Max Morelli® (n = 10). Qualitative evaluation of the bracket surface was performed using SEM, whereby surface features were described and compared. The elemental composition was analyzed by EDS. According to surface analysis,groups ABZ and RL showed a homogeneous surface, with better finishing, whereas the surfaces in groups NF and RM were rougher. The chemical components with the highest percentage were Fe, Cr and C. Groups NF and MR showed no nickel in their composition. In conclusion, the bracket surface of the ABZ and RL groups was more homogeneous, with grooves and pores, whereas the surfaces in groups NF and RM showed numerous flaws, cracks, pores and grooves. The chemical composition analysis confirmed that the nickel-free brackets had no Ni in their composition, as confirmed by the manufacturer’s specifications, and were therefore safe to use in patients with a medical history of allergy to this metal.


Subject(s)
Metals/chemistry , Nickel/chemistry , Orthodontic Brackets , Analysis of Variance , Alloys/chemistry , Corrosion , Materials Testing , Microscopy, Electron, Scanning , Reference Values , Spectrometry, X-Ray Emission , Statistics, Nonparametric , Surface Properties
9.
Dental press j. orthod. (Impr.) ; 19(4): 80-88, Jul-Aug/2014. tab, graf
Article in English | LILACS | ID: lil-725414

ABSTRACT

INTRODUCTION: Lateral cephalometric radiographs are traditionally required for orthodontic treatment, yet rarely used to assess asymmetries. OBJECTIVE: The objective of the present study was to use lateral cephalometric radiographs to identify existing skeletal and dentoalveolar morphological alterations in Class II subdivision and to compare them with the existing morphology in Class I and II relationship. MATERIAL AND METHODS: Ninety initial lateral cephalometric radiographs of male and female Brazilian children aged between 12 to 15 years old were randomly and proportionally divided into three groups: Group 1 (Class I), Group 2 (Class II) and Group 3 (Class II subdivision). Analysis of lateral cephalometric radiographs included angular measurements, horizontal linear measurements and two indexes of asymmetry that were prepared for this study. RESULTS: In accordance with an Index of Dental Asymmetry (IDA), greater mandibular dental asymmetry was identified in Group 3. An Index of Mandibular Asymmetry (IMA) revealed less skeletal and dental mandibular asymmetry in Group 2, greater skeletal mandibular asymmetry in Group 1, and greater mandibular dental asymmetry in Group 3. CONCLUSION: Both IDA and IMA revealed greater mandibular dental asymmetry for Group 3 in comparison to Groups 1 and 2. These results are in accordance with those found by other diagnostic methods, showing that lateral cephalometric radiography is an acceptable method to identify existing skeletal and dentoalveolar morphological alterations in malocclusions. .


INTRODUÇÃO: as telerradiografias laterais são tradicionalmente solicitadas para planejamento ortodôntico, mas raramente utilizadas para avaliar assimetrias. OBJETIVO: o objetivo do presente estudo foi utilizar as telerradiografias laterais para identificar as alterações morfológicas esqueléticas e dentoalveolares existentes na má oclusão de Classe II subdivisão e compará-las com a morfologia existente nas más oclusões de Classe I e II. MÉTODOS: noventa telerradiografias laterais iniciais de adolescentes brasileiros de ambos os sexos, com idade cronológica entre 12 e 15 anos, foram divididas em três grupos randomizados e proporcionais: Grupo 1 (Classe I), Grupo 2 (Classe II) e Grupo 3 (Classe II subdivisão). A análise das telerradiografias laterais envolveu mensurações angulares, mensurações lineares horizontais e dois índices de assimetria, estipulados para o presente estudo. RESULTADOS: foi identificada, de acordo com o Índice de assimetria dentária (IAD), uma maior assimetria dentária inferior no Grupo 3. O Índice de assimetria mandibular (IAM) revelou menor assimetria esquelética e dentária no Grupo 2, maior assimetria esquelética no Grupo 1 e maior assimetria dentária inferior no Grupo 3. CONCLUSÃO: o IAD e o IAM mostraram maior assimetria dentária inferior no Grupo 3 do que nos Grupos 1 e 2. Esses resultados estão de acordo com os encontrados em outros métodos de diagnóstico, indicando que a telerradiografia lateral é um método aceitável para avaliar alterações morfológicas esqueléticas e dentoalveolares nas más oclusões. .


Subject(s)
Adolescent , Child , Female , Humans , Male , Cephalometry/methods , Facial Asymmetry , Malocclusion, Angle Class I , Malocclusion, Angle Class II , Alveolar Process , Chin , Dental Arch , Facial Asymmetry/classification , Facial Bones , Incisor , Malocclusion, Angle Class II/classification , Mandible , Maxilla , Molar , Nasal Bone , Palate , Retrognathia/classification , Retrognathia , Sella Turcica
10.
Rev. Clín. Ortod. Dent. Press ; 12(4): 91-100, ago.-set. 2013. ilus
Article in Portuguese | LILACS, BBO | ID: lil-707663

ABSTRACT

Pacientes com agenesia de incisivo lateral superior devem ter em seu planejamento considerações estéticas e funcionais, importantes para o sucesso do tratamento, independentemente se escolha do tratamento for fechamento ou abertura e manutenção do espaço para uma reabilitação com prótese. Essa escolha vai depender de fatores como estrutura esquelética, dentária e perfil. Crianças e adolescentes são o grupo de indivíduos mais expostos ao traumas e fraturas dos incisivos centrais superiores, devido às atividades que realizam. O diagnóstico adequado e uma boa terapêutica são essenciais para o sucesso do tratamento. Esse artigo teve como objetivo relatar um caso de agenesia de incisivo lateral superior juntamente com o envolvimento de uma fratura radicular do incisivo central superior. O tratamento ortodôntico foi realizado a contento, com prognóstico favorável para a permanência do incisivo fraturado em posição estética e funcional.


Subject(s)
Humans , Female , Child , Anodontia/therapy , Orthodontics, Corrective , Interprofessional Relations , Tooth Injuries
11.
Dental press j. orthod. (Impr.) ; 18(4): 43-52, July-Aug. 2013. ilus, tab
Article in English | LILACS | ID: lil-695119

ABSTRACT

OBJECTIVE: The purpose of the study was to evaluate the influence of the skeletal maturation in the mandibular and dentoalveolar growth and development during the Class II, division 1, malocclusion correction with Balters bionator. METHODS: Three groups of children with Class II, division 1, malocclusion were evaluated. Two of them were treated for one year with the bionator of Balters appliance in different skeletal ages (Group 1: 6 children, 7 to 8 years old and Group 2: 10 children, 9 to 10 years old) and the other one was followed without treatment (Control Group: 7 children, 8 to 9 years old). Lateral 45 degree cephalometric radiographs were used for the evaluation of the mandibular growth and dentoalveolar development. Tantalum metallic implants were used as fixed and stable references for radiograph superimposition and data acquisition. Student's t test was used in the statistical analysis of the displacement of the points in the condyle, ramus, mandibular base and dental points. Analysis of variance one-fixed criteria was used to evaluate group differences (95% of level of significance). RESULTS: The intragroup evaluation showed that all groups present significant skeletal growth for all points analyzed (1.2 to 3.7 mm), but in an intergroup comparison, the increment of the mandibular growth in the condyle, ramus and mandibular base were not statically different. For the dentoalveolar modifications, the less mature children showed greater labial inclination of the lower incisors (1.86 mm) and the most mature children showed greater first permanent molar extrusion (4.8 mm).


OBJETIVO: avaliar a influência da maturação óssea no processo de crescimento e de desenvolvimento mandibular e dentoalveolar durante a correção da Classe II, divisão 1, com o Bionator de Balters. MÉTODOS: foram avaliados três grupos de crianças com Classe II, divisão 1. Dois grupos foram tratados por um ano com o aparelho Bionator de Balters, em diferentes idades esqueléticas (Grupo 1: 6 crianças, com 7 a 8 anos de idade; e Grupo 2: 10 crianças, com 9 a 10 anos); e um grupo sem tratamento (Grupo controle: 7 crianças, com 8 a 9 anos). Telerradiografias laterais em norma de 45º foram utilizadas para a avaliação do crescimento mandibular e para o desenvolvimento dentoalveolar. Implantes metálicos de tântalo foram usados como referência fixa e estável para sobreposições radiográficas e aquisição de dados. Na análise estatística do deslocamento de pontos localizados na região de côndilo, corpo e base mandibular e de pontos dentários, foi empregado o teste t de Student; para avaliar as diferenças entre os grupos, usou-se a análise de variância a um critério de classificação (nível de significância de 95%). RESULTADOS: os grupos, quando avaliados individualmente, apresentaram crescimento de todos os pontos esqueléticos de forma significativa (1,2 a 3,7mm); porém, quando comparados entre si, a quantidade de crescimento na região do côndilo, ramo e base da mandíbula não foi estatisticamente diferente. Quanto às alterações dentárias, ocorreu maior inclinação dos incisivos inferiores para vestibular (1,86mm) nos pacientes menos maduros, e maior extrusão dos primeiros molares permanentes (4,8mm) nos pacientes mais maduros.


Subject(s)
Child , Female , Humans , Male , Alveolar Process/growth & development , Dental Arch/growth & development , Malocclusion, Angle Class II/therapy , Mandible/growth & development , Maxillofacial Development/physiology , Orthodontic Appliances, Functional , Orthodontics, Corrective/instrumentation , Age Determination by Skeleton , Analysis of Variance , Alveolar Process , Cephalometry/methods , Dental Arch , Malocclusion, Angle Class II/physiopathology , Mandible
12.
J. Health Sci. Inst ; 31(1)jan.-mar. 2013. tab
Article in English | LILACS | ID: lil-684771

ABSTRACT

To correlate facial type measurements of Caucasian individuals with transverse dimensions of normal occlusion arches. Methods -Twenty-one pairs of dental models were selected according to the following inclusion criteria: presence of all permanent teeth from 1st molar to 1st molar; normal occlusion; no prosthetic crowns; no previous orthodontic treatment and 2 mm or less of crowdings or spacings. The cephalometric measurements of lateral cephalometric X-ray of the same individuals were taken and tabulated.To evaluate the repetition of arch measurements, paired Student's t-test and Pearson's correlation coefficient were used. The relationship between the measurements was analysed by using the Pearson's correlation. Results - The repetition of the measurements showed high correlation and no systematic error. In the comparison between the measurements, a moderate negative correlation was observed between facial axis angle and the measurements Upper and Lower 6-6, whereas a positive correlation was observed between dentition height and the latter. Conclusion - It was observed a negative correlation between facial axis angle and upper and lower inter-molar distance as well as a positive correlation between dentition height and upper and lower inter-molar distance...


Correlacionar medidas do tipo facial, em indivíduos leucodermas, com dimensões transversas das arcadas em oclusão normal. Métodos -Vinte e um pares de modelos de gesso foram selecionados de acordo com os requisitos de inclusão: presença de todos os dentes permanentes de 1° molar a 1° molar; oclusão normal; sem coroas protéticas; nenhum tratamento ortodôntico prévio e apinhamentos ou espaçamentos menores ou iguais a 2 milímetros. As medidas cefalométricas das telerradiografias laterais destes mesmos indivíduos foram consultadas e tabuladas. Para a avaliação da repetibilidade das medidas das arcadas foram utilizados o teste t de Student pareado e o coeficiente de Pearson. O grau de associação entre as medidas foi analisado pelo coeficiente de correlação de Pearson. Resultados - A repetibilidade de medidas demonstrou alta correlação e ausência de erro sistemático. Na comparação entre as medidas houve correlação negativa moderada do ângulo do eixo facial com as medidas Sup 6-6 e Inf 6-6 e correlação positiva da altura da dentição com as medidas Sup 6-6e Inf 6-6. Conclusão - Houve correlação negativa entre ângulo do eixo facial e as distâncias intermolares superiores e inferiores e, correlação positiva entre a altura da dentição e as distâncias intermolares superiores e inferiores...


Subject(s)
Humans , Male , Female , Child , Adolescent , Dental Arch , Models, Dental , Face
13.
J. Health Sci. Inst ; 31(1)jan.-mar. 2013. ilus
Article in Portuguese | LILACS | ID: lil-684787

ABSTRACT

No estudo das más oclusões, podem estar presentes tanto alterações dentárias como esqueléticas. Nos casos de má oclusão Classe III pode-se observar retrusão maxilar, protrusão mandibular ou a combinação destes sinais, e, muitas vezes associadas a uma atresia maxilar que geralmente se manifesta por mordidas cruzadas anteriores, posteriores, uni ou bilaterais. Este relato de caso clínico tem como objetivo avaliar os efeitos no perfil facial e na oclusão da terapia ortodôntica interceptativa. O tratamento realizado com expansão do arco superior e protração maxilar foi executado em idade bastante jovem para que atuasse efetivamente no sistema sutural circumaxilar e o efeito ortopédico fosse facilitado. A máscara facial utilizada apoia-se em dois pontos da face e permite um reposicionamento maxilar anterior. A colaboração do paciente é importante para alcançar o sucesso do tratamento, isto porque o tempo de uso da máscara ainda nesta fase de crescimento e desenvolvimento é primordial para que os efeitos faciais e oclusais aconteçam. É importante ressaltar que os pacientes com má oclusão de Angle Classe III devem ser acompanhados até o final do crescimento...


In malocclusion studies, may happen not only dental discrepancies but even skeletal discrepancies. In Class III malocclusion can be observed underdeveloped maxilla, mandible protraction or both of them, and, in most of the times associated with a narrow maxilla that causes anterior or posterior crossbites, in one side or in two sides. The aim of this case report is to evaluate the facial profile and occlusal effects of interceptive orthodontics therapy. The treatment with upper arch expansion and maxilla protraction was done in an early age to be effective in the circummaxillary sutural system and to make the orthopedic effect easier. The facial mask used is positioned on two facial points and allows an anterior maxillary replacement. Patients' compliance is important to reach treatment success, this because using the mask still in this growth and development phase is essential to make the facial and occlusal effects happen. It is important to mention that patients with Angle Class III malocclusion need to be followed till the end of their growth...


Subject(s)
Humans , Male , Infant, Newborn , Diagnosis , Malocclusion, Angle Class III , Orthodontics, Interceptive
14.
RSBO (Impr.) ; 10(1): 40-48, Jan.-Mar. 2013. ilus, tab
Article in English | LILACS | ID: lil-695911

ABSTRACT

Introduction and Objective : The synthetic intermaxillary elastic emerged as an alternative for clinical use in patients with latex sensitivity. However, there are disagreements about this elastic protocol use according to the force degradation. The aim of this study was to evaluate, in vitro, the forces generated by latex and synthetic elastics over time. Material and methods: Sample size of 840 elastics were used (420 latex and 420 synthetic), delivering medium strength (Dental Morelli®) with internal diameter of 1/8", 3/16", 1/4" and 5/16". The elastics were randomly divided into 7 groups according to the time of the force measuring and immersed into distilled water at 37°C. To measure the force in each group, the elastics were stretched in six progressive increases of 100% of its internal diameter with the aid of a testing machine Emic and measured up to 72 hours. Data were analyzed with SPSS 16.0, using one-way analysis of variance (ANOVA). Results: Immediate force level of synthetic elastics was statistically higher than latex elastics in all strains, for the same size. However, the latex elastics mean forceslightly decreased over time, while the synthetic elastics presented an abrupt decrease. Conclusion: In view of these findings, Sudanese homemade alcoholic beverages cause oral epithelial atypical changes, which lead to oral precancerous and cancerous lesions. OEFC is a useful procedure for detection and assessment of oral ET.

15.
Ortodontia ; 45(1): 25-32, jan.-fev. 2012. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-713851

ABSTRACT

Esta pesquisa avaliou in vitro a resistência ao cisalhamentode bráquetes ortodônticos fotopolimerizados com o arco de plasma, odiodo emissor de luz (LED) e a luz halógena convencional em diferentestempos. Bráquetes foram colados em 60 pré-molares superioreshumanos, divididos em cinco grupos. Nos grupos 1 e 2 utilizou-se a luzarco de plasma por três e seis segundos, respectivamente; nos grupos3 e 4 utilizou-se o LED por cinco e dez segundos, respectivamente; nogrupo 5 utilizou-se a luz halógena por 40 segundos. Os corpos de provaforam armazenados em água destilada em temperatura ambiente e,após 24 horas dos procedimentos de colagem, foram submetidos aosensaios mecânicos na máquina universal MTS-Material Test System. Paraa complementação dos resultados, também foi realizada a avaliação e aclassificação do padrão de descolagem dos bráquetes utilizando o lAR.Os resultados foram analisados por meio da análise de variância (Anova,seguida do teste SNK de Tukey para comparação múltipla de médias.Nãohouve diferenças entre os grupos 2, 4 e 5, as quais foram maioresque as médias dos grupos 1 e 3, iguais entre si. Os escores do lAR nãomostraram diferenças quanto à interface de descolagem entre os trêstipos de luz em todos os tempos testados. A luz arco de plasma e o LEDpodem ser utilizados por tempos reduzidos, dentro de certos limites,em relação à luz halógena na colagem de bráquetes ortodônticos, semperda de resistência ao cisalhamento.


This study evaluated in vitro the shear bond strength ofbraekets bonded with xenon plasma are light, light-emitting diode (LED)and conventional halogen light using different curing times. Bracketswere bonded to the bueeal surfaee of 60 human maxillary premolarsalloeated to tive groups. In groups 1 and 2, the resin was cured with theplasma are for three and six seconds (5), respectively; in groups 3 and4, the LED was used for tive and ten 5, respectively; and in group 5, thehalogen light was used for 40 s. The specimens were stored in waterfor 24 hours and subjected to a shear force until bracket failure. Thedebonding pattern was classified according to the adhesive remnant index(ARI). The results were assessed by Anova and the SNK post-hoe test.No differenees were deteeted among groups 2, 4 and 5, whieh showedhigher averages than groups 1 and 3, whieh were not different betweenthemselves. The ARI scores showed no differenees among the three typesof light sourees in ali times tested. Plasma are and LED lights ean be usedwith shorter euring times, within certain limits, than conventional halogenlight for bonding orthodontie brackets, without decreasing bond strength.


Subject(s)
Curing Lights, Dental , Light-Curing of Dental Adhesives , Lasers, Semiconductor , Orthodontic Brackets , Shear Strength , Bicuspid , Phototherapy
16.
Ortodontia ; 45(1): 43-48, jan.-fev. 2012. tab
Article in Portuguese | LILACS, BBO | ID: lil-713856

ABSTRACT

A inter-relação Ortodontia e Endodontia vem sendo esclarecida com aevolução da Odontologia baseada em evidências científicas. Contudo,poucos estudos relacionam o reparo periapical de lesões com movimentaçãoortodôntica. Sendo assim, o objetivo deste estudo foi avaliar a evidênciacientífica disponível sobre o reparo periapical de dentes tratadosendodonticamente durante a movimentação ortodôntica. A estratégiausada foi a de busca eletrônica com palavras-chaves e critérios incluindoartigos publicados até julho de 2011. Foi também realizada avaliaçãoqualitativa da metodologia dos artigos. Embora um significativo númerode estudos reportarem o assunto, apenas dois artigos preencheram oscritérios para inclusão nesta revisão sistemática. Os resultados obtidosna literatura sugerem que o tratamento ortodôntico deve ser interrompidopara realização do tratamento endodôntico. Durante esta terapia,o emprego de curativo de demora à base de hidróxido de cálcio por nomínimo 14 dias e de cimento endodôntico com adequada propriedadebiológica estão indicados. Após esta fase, a movimentação ortodônticado dente tratado endodonticamente pode ser retomada sem necessidadede período de espera.


The relationship of Orthodontics and Endodontics is beingclarified with the development of evidence-based dentistry. However, fewstudies have reported the repair of periapicallesions with orthodontictreatment. Therefore, the aim of this study was to evaluate the availableevidence on periapical repair of endodontically treated teeth duringorthodontic movement. The strategy used was the electronic searchwith keywords and criteria including studies published up to July 2011. Itwas also carried out qualitative assessment of the articles methodology.Although a significant number of studies have reported this topic, onlytwo filled the criteria for inclusion in this systematic review. The resultsobtained in the literature suggest that orthodontic treatment should beinterrupted to perform endodontic treatment. During this therapy, theuse of root canal dressing based on calcium hydroxide for at least 14days, and sealer with adequate biological property are indicated. Afterthis phase, orthodontic movement of the endodontically treated teethcan be resumed without waiting period.


Subject(s)
Endodontics , Tooth Movement Techniques , Orthodontics , Periapical Tissue
17.
Ortho Sci., Orthod. sci. pract ; 5(20): 513-519, 2012. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-729313

ABSTRACT

Propõe-se com este estudo, avaliar a posição anteroposterior da mandíbula de crianças com má oclusão Classe II, divisão 1 de Angle, comparar dois diferentes métodos de avaliação da posição da mandíbula e verificar se há correlação entre esses dois métodos de avaliação. Foram selecionadas 26 crianças brasileiras, leucodermas, dolicofaciais, com má oclusão Classe II, divisão 1, com idades variando de 7 anos e 8 meses a 9 anos e 6 meses. A avaliação da posição anteroposterior da mandíbula foi realizada com a utilização de telerradiografias em norma lateral e foram utilizadas as grandezas cefalométricas angular SNB e linear Pog-Nperp. Com base nos resultados obtidos, concluiu-se que a grandeza cefalométrica SNB identificou mais crianças com retrusão mandibular do que a grandeza cefalométrica Pog-Nperp; o aumento da inclinação da base anterior do crânio pode ter diminuído os valores das grandezas cefalométricas SNB; a grandeza cefalométrica Pog-Nperp minimiza possibilidade de erro no posicionamento anteroposterior da mandíbula, uma vez que elimina a variável inclinação da base anterior do crânio; nenhuma das grandezas cefalométricas utilizadas eliminam a influência do posicionamento do ponto Násio no sentido anteroposterior e vertical e a correlação entre as grandezas cefalométricas SNB e Pog-Nperp é muito baixa


In this study, it is proposed to evaluate the anteroposterior position of mandible in children with Angle Class II, division 1 malocclusions, to compare two different methods of evaluating the jaw position and verifying the correlation between these two methods. We selected 26 Brazilian children with vertical growth pattern and Angle Class II, division 1 malocclusions, aged between 7 years and 8 months to 9 years and 6 months. The evaluation of the anteroposterior position of the mandible was performed with the use of lateral cephalograms by cephalometric angular SNB and linear Pog-Nperp. Based on the results obtained, it was concluded that the SNB identified more children with mandibular retrusion than Pog-Nperp; the increased tip of the SN plane may have decreased values of SNB; Pog-Nperp minimizes the possibility of error in the anteroposterior position of the mandible, since it eliminates the variable tip of the anterior skull base (SN plane); none of the cephalometric measurements used are able to eliminate the influence of the nasion point in the anterior-posterior and vertical position; correlation between SNB and Pog-Nperp is very low.


Subject(s)
Humans , Child , Cephalometry , Malocclusion, Angle Class II , Mandible
18.
Ortodontia ; 44(5): 427-432, set.-out. 2011. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-713830

ABSTRACT

O objetivo do estudo foi avaliar a degradação de força dos elásticos sintéticosao longo do tempo por meio de ensaios biomecânicos dinâmicos, a fim de buscarparâmetros clínicos de qual tamanho de elástico e frequência de troca devemos utilizarnas terapias ortodônticas. Utilizaram-se 240 elásticos da Dental Morelli, tamanho 1/8",3/16", 1/4" e 5/16" de força média, divididos em quatro grupos. A cada grupo forammensuradas forças em tempos diferentes, de imediato a 72 horas após imersão emágua destilada a 37°C mantidas em estufa e distendidos em 600% do seu diâmetrointerno inicial. Os ensaios de tração foram realizados em máquina de ensaios universalEmic DL2000, imersos em água destilada mantida a 37°C. Os dados foram analisadospor meio de software SPSS versão 16.0, através da Análise de Variância a um critério(One-Way)com pós-teste de Tukey. Verificou-se um padrão de degradação de força maiorda mensuração imediata até 24 horas em todos os tamanhos de elásticos sintéticos, apartir da qual se observa uma diminuição da força progressivamente menor, com exceçãodo elástico 5/16", cuja maior redução de força ocorreu em 12 horas. Concluiu-seque: os elásticos sintéticos Dental Morelli sofreram significativa degradação de força aolongo do tempo, com redução de aproximadamente 70% da força inicial em 24 horasde estiramento, seguida de uma diminuição progressivamente menor; a quantidade deestiramento para uma força ideal em terapias intermaxilares depende da distância entreos pontos de fixação do elástico, sendo necessária a consulta nas tabelas para escolhade tamanho, força e frequência de substituição.


This study aimed to evaluate the force degradation of synthetic elastics overtime using dynamic biomechanical tests in order to find clinical parameters of what sizeof elastic and frequency of exchange should be used in orthodontic therapy. It was used240 elastics of Dental MoreI/i, sizes 1/8", 3/16", 1/4 "and 5/16", medium force, dividedin four groups. In each group was measured forces at different times, from immediateto 72 hours after immersion in water at 37°C and incubated stretched to 600% of ttsinitial inner diameter. Tensile tests were performed on a universal testing machine EMICDL2000 submerged in distil/ed water maintained at 37°C Data were analyzed using SPSSversion 16.0, by the Analysis of Variance !One-Way) with Tukey's post test. There was agreater increase in pattern of force decay of immediate measurement until 24 hours in allsizes of synthetic elastics, from which it was observed a decrease in force progressivelysmaller, with the exception of 5/16" elastic with a maximum force decay occurred at12h. It was concluded that: the elastic synthetic Dental Morelli suffered significant forcedegradation over time, with reduction of approximately 70% of the initial force during 24hours of stretching, fol/owed by a progressively smal/er decrease; the amount of stretchfor a ideal force in intermaxil/ary therapies depends on the distance between the pointsof attachment of elastic, being necessary to consult the tables to choose the size, forceand frequency of replacement.


Subject(s)
Biomechanical Phenomena , Data Interpretation, Statistical , Elastomers
19.
Rev. Clín. Ortod. Dent. Press ; 9(6): 79-91, dez. 2010-jan. 2011. ilus
Article in Portuguese | LILACS, BBO | ID: lil-575406

ABSTRACT

O aparelho Jasper Jumper foi desenvolvido como um dispositivo ortopédico fixo conectado aos arcos de nivelamento superior e inferior visando a correção da Classe II por meio da restrição do crescimento maxilar (efeito extrabucal), estímulo do crescimento mandibular (efeito ativador) e/ou por mudanças dentoalveolares.


Subject(s)
Humans , Female , Child , Orthodontic Appliances , Mandibular Advancement , Malocclusion, Angle Class II/therapy
20.
Rev. Clín. Ortod. Dent. Press ; 9(3): 26-34, jun.-jul. 2010. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-562638

ABSTRACT

O diagnóstico e o planejamento constituem etapas fundamentais para o sucesso do tratamento ortodôntico, nas quais o ortodontista deve ter inúmeros elementos que contribuem na tomada das decisões mais acertadas. O set-up, ou montagem de diagnóstico em modelo, é um importante recurso no planejamento da terapia ortodôntica corretiva. Consiste no reposicionamento dos dentes previamente removidos dos modelos de estudo e remontados sobre a base remanescente dos mesmos. Quando corretamente confeccionado, o set-up permite uma visualização tridimensional prévia dos problemas e limitações do caso, auxiliando na tomada de decisões quanto às exodontias em casos com problemas de espaços, à quantidade de perda de ancoragem, extensão e tipo de movimentação dentária, discrepância do volume dentário interarcadas, entre outros, indicando a melhor opção para o tratamento. Este trabalho expõe etapas importantes para sua confecção, sistema de avaliação e sua aplicação na elaboração de planos de tratamento ortodôntico.


Subject(s)
Humans , Diagnosis, Oral , Orthodontics, Corrective , Patient Care Planning , Calcium Sulfate
SELECTION OF CITATIONS
SEARCH DETAIL